Abstract
BackgroundType C pelvic fractures (AO/OTA) are severe injuries that frequently lead to bleeding and hemodynamic instability. Pelvic binders play a crucial role in their initial management. Placement at the correct level in the prehospital setting is challenging. The aim of this study was to compare two pelvic binders regarding their effectiveness in reducing intrapelvic volume and increasing intrapelvic pressure in patients with type C pelvic fractures (AO/OTA) when applied at three different levels.MethodsRotationally and vertically unstable pelvic injuries (AO/OTA classification 61-C1.1) were produced in five fresh-frozen human cadaveric specimens. Intrapelvic volume, vesical pressure and compression pressure within the pubic symphysis and the sacroiliac joint were measured when applying a SAM Pelvic Sling II and a T-POD at the level of the greater trochanter as well as levels higher and lower than recommended.ResultsComparison of the two pelvic binders positioned at the recommended level (greater trochanter) showed no significant difference in volume reduction (13.85 ± 31.37 cm3, p = 0.442), however, increase in vesical pressure was significantly higher when using the T-POD (5.80 ± 3.27 cmH2O, p = 0.017). When positioned at the level of the iliac crest, vesical pressure increase and intrapelvic volume reduction were significantly greater with the T-POD (14.00 ± 8.57 cmH2O, p = 0.022 and 10.45 ± 5.45 cm3, p = 0.031 respectively). Application of the SAM Pelvic Sling II below the greater trochanter led to a significantly greater decrease in volume (-32.26 ± 7.52 cm3, p = 0.003) than the T-POD. Comparison of the recommended attachment level with incorrect positioning led to no significant differences for the T-POD, while the SAM Pelvic Sling II achieved a significantly lower volume reduction when placed at the iliac crest (40.15 ± 14.57 cm3, p = 0.012) and a significantly lower increase in vesical pressure when applied below the greater trochanter (3.40 ± 1.52 cmH2O, p = 0.007).ConclusionDirect comparison of the two pelvic binders showed that the T-POD achieved significantly greater results when applied at the recommended level and was less susceptible to incorrect positioning. These outcomes support the preferred use of the T-POD for prehospital emergency pelvic stabilisation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.