Abstract
Purpose: The purpose was to describe comparative analysis of the surgical outcome of percutaneous K-wire fixation of bony mallet fingers reduced with towel clip and 18-gauge needle. Methods: We analyzed the bony mallet finger patients with more than twelve months follow-up after percutaneous K-wire fixation. The patients were randomly divided into two groups. Eighteen fingers were treated with closed reduction using towel clip and 18 other fingers were treated with closed reduction using 18-gauge needle. Results: Radiographs showed bony union and no subluxation in all cases after K-wire removal. The average extension lag was 2.8°/1.9°, and range of motion of distal interphalangeal joint was 70.3°/75° respectively. According to Crawford’s criteria, excellent results were obtained in 9/11 fingers, good results in 8/7 fingers, and poor result in 1/0 finger, respectively. Conclusion: 18-gauge needle reduction in percutaneous K-wire fixation is considered less invasive and useful method for treatment of bony mallet finger with comparable results with towel clip reduction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Korean Society for Surgery of the Hand
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.