Abstract

The aim of this study is to compare the surgical outcomes of single-port laparoscopic surgery (SPLS) and single-port robotic surgery (SPRS). We retrospectively analyzed patients who underwent a hysterectomy, ovarian cystectomy, or myomectomy with SPLS or SPRS from January 2020 to July 2022. Statistical analyses were performed using the SPSS chi-square test and student's t-test. A total of 566 surgeries including single-port laparoscopic hysterectomy (SPLH; n = 148), single-port robotic hysterectomy (SPRH; n = 35), single-port laparoscopic ovarian cystectomy (SPLC; n = 207), single-port robotic ovarian cystectomy (SPRC; n = 108), single-port laparoscopic myomectomy (SPLM; n = 12), and single-port robotic myomectomy (SPRM; n = 56). The SPRH, SPRC, and SPRM groups had a shorter operation time than the SPLS group, although the results were not statistically significant (SPRH vs. SPLH, p = 0.134; SPRC vs. SPLC, p = 0.098; SPRM vs. SPLM, p = 0.202). Incisional hernia occurred as a postoperative complication in two patients only in the SPLH group. Postoperative Hb changes were lower in the SPRC and SPRM groups than in the SPLC and SPLM groups (SPRC vs. SPLC, p = 0.023; SPRM vs. SPLM, p = 0.010). Our study demonstrated that the SPRS had comparable surgical outcomes when compared to the SPLS. Therefore, the SPRS should be considered a feasible and safe option for gynecologic patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call