Abstract

The long-term prognosis of arteriovenous (AV) polytetrafluoroethylene (PTFE) hemodialysis grafts is dissatisfying. Responsible for the poor outcome is a stenosis of the venous anastomosis. This originates from both pseudointimal (PI) and neointimal hyperplasia (IH) development. Although cuffed grafts have a better short-term prognosis than straight grafts, the late results of both types are poor. This current study aimed to compare both arteriovenous straight and Venaflo-type (Bard, Tempe, Ariz) prostheses in an animal study with regard to patency, PI, and IH development. Sixteen iliac arteriovenous expanded polytetrafluoroethylene (ePTFE) loops were inserted into 16 pigs. Animals were randomized into two groups. Group 1 animals received straight configured ePTFE grafts and group 2 animals received grafts with a Venaflo-type cuffed venous anastomosis. After insertion of the shunts and immediately before graft harvest, the shunt flows were measured. Six weeks after implantation, patency rates and development of pseudointima (PI) within the grafts were noted. The thickness of the venous intimal hyperplasia was measured using digital planimetry. Patency rates after 6 weeks were 25% for straight and 62% for Venaflo-type grafts. In both groups a significant decrease of the graft blood flow compared with the preoperative levels was observed, which was attributed to the marked development of pseudointima. The reduction in flow at graft harvest was greater in the straight ePTFE group (658 ± 68 vs 260 ± 42 mL/min, P < .05) than for the Venaflo-type grafts (770 ± 107 vs 661 ± 284 mL/min, P = ns), but the differences between the groups were statistically not significant. A marked pseudointima developed in the Venaflo cuff. The PI development was significantly higher in the graft hood (2.9 ± 0.6 mm) than in the heel (2.5 ± 0.4 mm, P < .05). In both groups, an intimal hyperplasia formed on the vein wall just opposite to the graft inflow. The intimal hyperplasia development was more pronounced in the straight configured shunts. The results of the present study confirm the inferior clinical results of ePTFE grafts used for hemodialysis access. Although the patency rates of cuffed grafts were superior, in both graft types a significant pseudointima leading to subtotal graft stenosis was observed in all grafts. Both straight and Venaflo-grafts. The Venaflo grafts have a slightly bettertype cuffed ePTFE grafts have major hemodynamic drawbacks that have to be addressed in future graft design efforts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.