Abstract

ObjectiveTo compare long-term effectiveness of Standard (UV intensity: 3 mW/cm2, duration: 30 min) vs Accelerated (UV intensity: 9 mW/cm2, duration: 10 min) corneal cross-linking (CXL) for stabilising keratoconus.MethodsData for this observational study were captured through a web-based registry system from the routine clinical practice (15 sites across Australia, New Zealand and Italy). The outcomes were compared using mixed-effects regression models. A total of 100 eyes (75 patients) who had standard CXL and 76 eyes (66 patients) who had accelerated CXL, with a follow-up visit at five-year post-CXL were included.ResultsBoth CXL protocols were effective and safe in stabilising keratoconus and improving outcomes. The adjusted mean changes (95% CI) in outcomes were better in standard CXL than in accelerated CXL [visual acuity gain, 10.2 (7.9–12.5) vs 4.9 (1.6–8.2) logMAR letters; pinhole visual acuity 5.7 (3.5–7.8) vs 0.2 (−2.2 to 2.5) logMAR letters; Kmax −1.8 (−4.3 to 0.6) vs 1.2 (−1.5 to 3.9)D; K2 −0.9 (–2.2 to 0.3) vs 0.1 (−1.3 to 1.6)D; MCT –3.0 (−13.7 to 7.7) vs −11.8 (−23.9 to 0.4) µm (p values for visual acuity, pinhole visual acuity, Kmax: <0.05; for K2 and MCT: >0.05)]. The frequency of adverse events at the 5-year follow-up visit was low in both groups [standard, 5 (5%; haze 3; scarring 1, epithelial defect 1) and accelerated 3 (3.9%; haze 2, scarring 1)].ConclusionsBoth standard and accelerated CXL were safe and effective procedures for stabilising keratoconus in the long term. The standard CXL resulted in greater improvements in visual acuity and keratometry.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call