Abstract
Single-event upset (SEU) is investigated using heavy ion and pulsed laser. The measured SEU cross sections of D and DICE flip-flops are compared. Measurement results indicate pulsed laser is capable of inducing similar SEU to those induced by heavy ion. 3D-TCAD simulation is performed to investigate the factors to impact pulsed laser induced SEU. Simulation results show that the beam spot size significantly impacts SEU cross sections in both low and high laser energy while the variation of the equivalent LET only impacts SEU cross sections in the low laser energy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.