Abstract

Study Design:Clinical case series.Objectives:To compare the short-term (≤1 year) radiographical and clinical outcomes between posterior lumbar interbody fusion (PLIF) with a titanium-coated poly-ether-ether-ketone (TCP) cage and PLIF with a three-dimensional porous titanium alloy (PTA) cage.Methods:Overall, 63 patients who had undergone 1- or 2-level PLIF since March 2015 were enrolled (median age, 71 years). The first 34 patients underwent PLIF with TCP cages (until June 2017) and the next 29 patients with PTA cages. Fusion status, vertebral endplate cyst formation (cyst sign: grade 0, none; grade 1, focal; and grade 2, diffuse), cage subsidence (grade 0, <1 mm; grade 1, 1–3 mm; and grade 2, >3 mm), and patient-reported quality of life (QOL) outcomes based on the Japanese Orthopaedic Association Back Pain Evaluation Questionnaire (JOABPEQ) were compared at 6 months and 1 year postoperatively between the 2 cage groups.Results:Cyst sign and cage subsidence grades were significantly lower in the PTA cage group than in the TCP cage group at 6 months postoperatively (cyst sign, p = 0.044; cage subsidence, p = 0.043). In contrast, the fusion rate and surgery effectiveness based on JOABPEQ at both 6 months and 1 year postoperatively were not different between the 2 groups.Conclusions:Patient-reported QOL outcomes were similar between the TCP and PTA cage groups until 1 year postoperatively. However, a higher incidence and severity of postoperative vertebral endplate cyst formation in patients with the TCP cage was a noteworthy radiographical finding.