Abstract

This paper investigates non-invasive techniques for annular two-phase flow analysis, focusing on liquid film characterization to understand the interfacial phenomena that are crucial for heat and mass transfer. Limited methods allow the study of the temporal and spatial evolution of liquid film, such as Planar Laser-Induced Fluorescence (PLIF). However, this method possesses optical challenges, leading to the need for improved techniques to mitigate refraction and reflection, such as Refractive Index Matching (RIM). This study utilizes an experimental annular flow facility to analyze both RIM and non-RIM PLIF over a range of liquid Reynolds numbers from 4200 to 10,400. Three configurations-PLIF RIM90, PLIF RIM40, and PLIF nRIM40-are compared from both qualitative and quantitative perspectives. In the quantitative analysis, key variables of the liquid film are measured, namely mean film thickness, disturbance wave height, and frequency. Variations in the analyzed variables indicate minor deviations, which are not likely to be caused by the technique used. However, all three methodologies exhibited errors that are estimated to be within a maximum of 10%, with a mean value of approximately 8%.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call