Abstract

IntroductionMost endovascular techniques are associated with patient and personal exposure to radiation during the procedure. Ionising radiation can cause deterministic effects, such as skin injury, as well as stochastic effects, which increase the long-term risk of malignancy. Endovascular operators need to be aware of radiation danger and take all necessary steps to minimise the risk to patients and staff. Some procedures, especially percutaneous peripheral artery revascularisation, are associated with increased radiation dose due to time-consuming operations. There is limited data comparing radiation dose during percutaneous coronary intervention (PCI) with percutaneous transluminal angioplasty (PTA) of peripheral arteries.AimTo compare the radiation dose in percutaneous coronary vs. peripheral interventions in one centre with a uniform system of protection methods.Material and methodsA total of 352 patients were included in the study. This included 217 patients undergoing PCI (single and multiple stenting) and 135 patients undergoing PTA (in lower extremities, carotid artery, renal artery, and subclavian artery). Radiation dose, fluoroscopy time, and total procedural time were reviewed. Cumulative radiation dose was measured in gray (Gy) units.ResultsThe total procedural time was significantly higher in PTA (PCI vs. PTA: 60 (45–85) min vs. 75 (50–100) min), p < 0.001. The radiation dose for PCI procedures was significantly higher in comparison to PTA (PCI vs. PTA: 1.36 (0.83–2.23) Gy vs. 0.27 (0.13–0.46) Gy), p < 0.001. There was no significant difference in the fluoroscopy time (PCI vs. PTA: 12.9 (8.2–21.5) min vs. 14.4 (8.0–22.6) min), p = 0.6. The analysis of correlation between radiation dose and fluoroscopy time in PCI and PTA interventions separately shows a strong correlation in PCI group (r = 0.785). However, a weak correlation was found in PTA group (r = 0.317).ConclusionsThe radiation dose was significantly higher during PCI in comparison to PTA procedures despite comparable fluoroscopy time and longer total procedure time in PTA. Fluoroscopy time is a reliable parameter to control the radiation dose exposure in coronary procedures. The increasing complexity of endovascular interventions has resulted in the increase of radiation dose exposure during PCI procedures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.