Abstract

Introduction: Enteric fever is the major health problem of developing country like India, with a notable morbidity and mortality. Isolation of Salmonella the causative agent from Blood is the standard laboratory method for diagnosis, but it is not available at PHC level. So, rapid and affordable diagnostic test like Widal tube and slide agglutination test are used. The present study was done to comparatively evaluate the Widal slide agglutination and tube agglutination test in detecting enteric fever.
 Methods: A total of 500 patients with clinical presentation suggestive of enteric fever were included in the study whose venous blood was collected. All the samples were tested for the presence of anti O and anti H agglutinins against S. typhi and S. paratyphi A by semi quantitative slide and quantitative tube agglutination tests as per standard protocols. The titers of 1:80 (O agglutinins) and 1:160 (H agglutinins) were taken as the significant titer for the diagnosis of enteric fever.
 Results: Out of 500 collected samples, 183 (36.6%) was positive by slide agglutination test, whereas, only 145 (29%) were positive by tube agglutination method. The slide test had a sensitivity of 97.2%, specificity of 88.1%, positive predictive value of 77% and negative predictive value of 98.7% as compared to Widal tube agglutination test.
 Conclusions: Due to high false positivity shown by slide test, it is suggested that serological diagnosis should not be made solely on the basis of slide test rather its results should be confirmed by using Widal tube agglutination test.
 Keywords: Enteric fever, Slide agglutination test, Widal tube agglutination test, Sensitivity, Specificity

Highlights

  • Enteric fever is the major health problem of developing country like India, with a notable morbidity and mortality

  • All the samples were tested for the presence of anti O and anti H agglutinins against S. typhi and S. paratyphi A by semi quantitative slide and quantitative tube agglutination tests as per standard protocols

  • Out of 500 collected samples, 183 (36.6%) was positive by slide agglutination test, whereas, only 145 (29%) were positive by tube agglutination method

Read more

Summary

Introduction

Enteric fever is the major health problem of developing country like India, with a notable morbidity and mortality. The present study was done to comparatively evaluate the Widal slide agglutination and tube agglutination test in detecting enteric fever. Enteric fever is a major public health problem in the developing countries such as India with significant morbidity and mortality where typhoid fever is very prevalent. The World Health Organization (WHO) estimate for annual global incidence of typhoid fever is about 21 million cases.[1,2,3] Typhoid fever has a case-fatality rate of 10-30%, without effective treatment. This number has been reduced to 1- 4% in those receiving appropriate antibiotic and supportive therapy. Laboratory diagnosis plays crucial role in confirming the clinical diagnosis of typhoid and contribute to the effective management and treatment of typhoid cases.[4,5,6]

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.