Abstract

Both prone position and high-frequency oscillatory ventilation (HFOV) have the potential to facilitate lung recruitment, and their combined use could thus be synergetic on gas exchange. Keeping the lung open could also potentially be lung protective. The aim of this study was to compare physiologic and proinflammatory effects of HFOV, prone positioning, or their combination in severe acute respiratory distress syndrome (ARDS). : Prospective, comparative randomized study. A medical intensive care unit. Thirty-nine ARDS patients with a Pao2/Fio2 ratio <150 mm Hg at positive end-expiratory pressure > or =5 cm H2O. After 12 hrs on conventional lung-protective mechanical ventilation (tidal volume 6 mL/kg of ideal body weight, plateau pressure not exceeding the upper inflection point, and a maximum of 35 cm H2O; supine-CV), 39 patients were randomized to receive one of the following 12-hr periods: conventional lung-protective mechanical ventilation in prone position (prone-CV), HFOV in supine position (supine-HFOV), or HFOV in prone position (prone-HFOV). Prone-CV (from 138 +/- 58 mm Hg to 217 +/- 110 mm Hg, p < .0001) and prone-HFOV (from 126 +/- 40 mm Hg to 227 +/- 64 mm Hg, p < 0.0001) improved the Pao2/Fio2 ratio whereas supine-HFOV did not alter the Pao2/Fio2 ratio (from 134 +/- 57 mm Hg to 138 +/- 48 mm Hg). The oxygenation index ({mean airway pressure x Fio2 x 100}/Pao2) decreased in the prone-CV and prone-HFOV groups and was lower than in the supine-HFOV group. Interleukin-8 increased significantly in the bronchoalveolar lavage fluid (BALF) in supine-HFOV and prone-HFOV groups compared with prone-CV and supine-CV. Neutrophil counts were higher in the supine-HFOV group than in the prone-CV group. Although HFOV in the supine position does not improve oxygenation or lung inflammation, the prone position increases oxygenation and reduces lung inflammation in ARDS patients. Prone-HFOV produced similar improvement in oxygenation like prone-CV but was associated with higher BALF indexes of inflammation. In contrast, supine-HFOV did not improve gas exchange and was associated with enhanced lung inflammation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.