Abstract

Compare prone and upright, stereotactic, and tomosynthesis-guided vacuum-assisted breast biopsies (prone DM-VABB, prone DBT-VABB, upright DM-VABB, and upright DBT-VABB) in a community-practice setting and review outcomes of ultrasound-occult architectural distortions (AD). Consecutive biopsies performed at two community-based breast centers from 2016 to 2019 were retrospectively reviewed. Technical details of each procedure and patient outcomes were recorded. Separate analyses were performed for ultrasound-occult ADs. Two sample t-tests and Fisher's exact test facilitated comparisons. A total of 1133 patients underwent 369 prone DM-VABB, 324 prone DBT-VABB, 437 upright DM-VABB, and 123 upright DBT-VABB with 99.2%, 100%, 99.3%, and 99.2% success, respectively (p-values > 0.25). Mean lesion targeting times were greater for prone biopsy (minutes: 6.94 prone DM-VABB, 8.54 prone DBT-VABB, 5.52 upright DM-VABB, and 5.51 upright DBT-VABB; p-values < 0.001), yielding longer total prone procedure times for prone biopsy (p < 0.001). Compared to DM-VABB, DBT-VABB used fewer exposures (p < 0.001) and more commonly targeted AD, asymmetries, or masses (p < 0.001). Malignancy rates were similar between procedures: prone DM-VABB 22.4%, prone DBT-VABB 21.9%, upright DM-VABB 22.8%, and upright DBT-VABB 17.2% (p-values > 0.19). One hundred forty of the 1133 patients underwent 145 biopsies for ultrasound-occult AD (143 DBT-VABB and 2 DM-VABB). Biopsy yielded 27 malignancies and 47 high-risk lesions (74 of 145, 51%). Malignancy rate was 20.7% after surgical upgrade of one benign-discordant and two high-risk lesions. All biopsy procedure types were extremely successful. The 20.7% malignancy rate for ultrasound-occult AD confirms a management recommendation for tissue diagnosis. Upright biopsy was faster than prone biopsy, and DBT-VABB used fewer exposures than DM-VABB. Our results highlight important differences between prone DM-VABB, prone DBT-VABB, upright DM-VABB, and upright DBT-VABB. Moreover, the high likelihood of malignancy for ultrasound-occult AD will provide confidence in recommending tissue diagnosis in lieu of observation or clinical follow-up. • Upright and prone stereotactic and tomosynthesis-guided breast biopsies were safe and effective in the community-practice setting. • The malignancy rate for ultrasound-occult architectural distortion of 20.7% confirms the management recommendation for biopsy. • Upright procedures were faster than prone procedures, and tomosynthesis-guided biopsy used fewer exposures than stereotactic biopsy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.