Abstract

This study was done to evaluate differences in pressure pain threshold, grip strength, manual dexterity and touch pressure threshold in the dominant and non-dominant hands of right- and left-handed subjects, and to compare findings within and between these groups. Thirty-nine right-handed and twenty-one left-handed subjects participated in the study. Pressure pain threshold was assessed using a dolorimeter, grip strength was assessed with a hand-grip dynamometer, manual dexterity was evaluated using the VALPAR Component Work Sample-4 system, and touch pressure threshold was determined using Semmes Weinstein monofilaments. Results for the dominant and non-dominant hands were compared within and between the groups. In the right-handed subjects, the dominant hand was significantly faster with the VALPAR Component Work Sample-4, showed significantly greater grip strength, and had a significantly higher pressure pain threshold than the non-dominant hand. The corresponding results for the two hands were similar in the left-handed subjects. The study revealed asymmetrical manual performance in grip strength, manual dexterity and pressure pain threshold in right-handed subjects, but no such asymme-tries in left-handed subjects.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call