Abstract

Japanese encephalitis is prevalent throughout the temperate and tropical regions of Asia and is caused by the Japanese encephalitis virus (JEV), a mosquito-borne viral pathogen. The plaque reduction neutralization test (PRNT) is currently recommended as the gold standard test for detecting human antibodies against JEV. The plaque assay is the most widely used method for detecting infectious virions and involves counting discrete plaques in cells. However, it is time-consuming, and results can be subjective (owing to analyst variability during manual plaque counting). The focus reduction neutralization test (FRNT), which is based on an immuno-colorimetric assay, can be used to automatically count foci formed by the JEV. Here, we compared the efficacy of PRNT and FRNT in measuring the neutralizing antibody titers using 102 serum samples from vaccinated and unvaccinated individuals. We observed positive correlations between these neutralization assays against the Nakayama and Beijing strains (R2 = 0.98 and 0.77, respectively). Thus, FRNT may be preferable to PRNT for evaluating the efficacy of JEV vaccines in large-scale serological studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.