Abstract

The photon interaction parameters such as mass attenuation coefficient (μ/ρ), effective atomic number (Z eff) and effective electron density (N el) must be identical for the phantom material and their tissue. In the present study, the μ/ρ, Z eff, and N el for muscle, breast, lung tissue have been computed, and their substitutes such as Griffith muscle, Griffith breast, Griffith lung, Alderson muscle A, Alderson muscle, and Alderson lung. Also compared were μ/ρ, Z eff, and N el for muscle, breast, lung tissue, and their substitutes. It can be shown that Alderson muscle B is better substitute for muscle than Griffith muscle and Alderson muscle A. Similarly, the photon interaction parameters of tissue substitutes of lung and breast with their original tissue were also compared.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.