Abstract

This paper presents the modelling and simulation of Static Synchronous Series Compensator (SSSC) in a two area system for Automatic Generation Control (AGC) under deregulated environment. The modelling of Thyristor Controlled phase Shifter (TCPS) is also carried out and comparison is made between SSSC and TCPS. A two area hydrothermal system under deregulated environment has been considered for this purpose. The devices are modeled and attempt has been made to incorporate these devices in the two area system thus improving the dynamic response of the system. The effect of these parameters on the system is demonstrated with the help of computer simulations. A systematic method has also been demonstrated for the modeling of this component in the system. Computer simulations reveal that due to the presence of SSSC along with TCPS, the dynamic performance of the system in terms of settling time, overshoot is greatly improved than that of without SSSC. DOI: http://dx.doi.org/10.11591/ijece.v1i1.21

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.