Abstract

Three hydrogen electrode-supported, large-scale solid oxide electrolysis cells (SOECs) with different composite air electrodes, namely LSM–YSZ, LSC–GDC, and LSCF–GDC (LSM, LSC, and LSCF cells, respectively), were compared for performance and degradation in the same three cell stack with an H2O/H2 ratio of 90/10. The initial SOEC performance increased in the following order: LSM, LSCF, and LSC. The three cells were operated at a constant current density of 0.50 A cm−2 for 640 h during hydrogen production at 750 °C. After the operation, the 10 cm × 10 cm large-scale single cell was divided equally into four subparts from the two diagonal parts with the steam or air inlet area and steam or air outlet area for post-mortem analysis. Delamination mainly occurred in the steam and air inlet areas of the LSM and LSC cells, with more severe delamination in the steam inlet area than that in the air inlet area. Agglomeration of Ni in the Ni–YSZ hydrogen electrode was observed in the LSM and LSCF cells, whereas honeycomb Ni was observed in the steam and air inlet areas of the LSC cell.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.