Abstract

Objective: To investigate the accuracy and clinical efficacy of percutaneous pedicle screw placement under O-arm navigation and traditional fluoroscopy in patients with thoracolumbar fractures without neurological symptoms. Methods: From July 2016 to July 2018, 72 patients with thoracolumbar fractures in Peking University International Hospital without neurological symptoms were divided into two groups, group A and group B. In group A, 36 patients underwent the surgery of percutaneous pedicle screw implantation under traditional fluoroscopy and 168 pedicle screws were inserted. In group B, 36 patients underwent the surgery of percutaneous pedicle screw implantation under O-arm guided fluoroscopy and 164 pedicle screws were inserted by the same surgeon. The general condition, operation condition, radiation dose, fluoroscopy time of single screw, screw placement time and accuracy, visual analogue score (VAS) score, Oswestry dysfunction index (ODI), kyphosis Cobb's angle, anterior edge height of 1 week and 6 months after surgery were compared. The data were compared with paired t test between the two groups. Results: There was no significant differences between the two groups in general condition, intraoperative blood loss, length of hospital stay, VAS, ODI, kyphosis Cobb's angle, and anterior edge height of the injured vertebra (all P>0.05). The operation time was (99±14) min in group A and (75±10) min in group B, the average screw setting time was (15.8±2.6) min in group A and (11.8±3.3) min in group B, the fluoroscopy time of each screw was (38.0±2.0) s in group A and (28.5±2.8) s in group B, the radiation dose of each surgery was (563±163) cGy/cm(2) in group A and (378±70) cGy/cm(2) in group B; the above-mentioned data of group A were all superior to those in group B and the differences between the two groups were all statistically significant (t=8.48, 5.73, 16.30, 6.25, all P<0.05). Rampersaud grading in group A was better than group B, and the differences between the two groups was statistically significant(χ(2)=12.2, P<0.05). Conclusion: The O-arm navigation system could not only provide high-definition navigation images and achieve high-precision navigation operations, which is more accurate than traditional pedicle screws placement, but also contribute to the reconstruction of spinal stability and reduce radiation dose, pedicle screws placement and operating time.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call