Abstract

BackgroundAlthough randomized controlled trials have confirmed oral tranexamic acid (TXA) can provide similar blood-sparing efficacy compared with intravenous (IV) TXA in total knee arthroplasty (TKA), some concerns do remain about thromboembolic events after such systemic administration. Many studies have confirmed that intra-articular (IA) application of TXA can show similar blood-saving efficacy with minimal levels of systemic absorption compared with IV TXA. However, it remains unclear whether the efficacy and safety of oral TXA administration is equal to or less than that of IA administration in TKA without the use of a tourniquet and drain. Thus, this study was to verify non-inferior efficacy and safety of oral TXA compared with IA TXA in primary TKA.MethodsA double-blind, randomized, controlled trial was performed to compare three oral doses of TXA (2 g of TXA 2 h before incision, and 1 g of TXA 6 and 12 h after surgery, respectively) with IA TXA (3 g of TXA in 100 mL of saline solution). One hundred forty-seven patients scheduled for TKA were randomized to one of the two interventions. The primary outcome was total blood loss. The secondary outcomes included reduction of hemoglobin concentration, clinical outcomes, blood coagulation values, thromboembolic complications, and transfusion rates.ResultsThe mean total blood loss was 788.8 mL in the oral TXA group compared with 872.4 mL in the IA TXA group, with no statistical significance (p > 0.05). There were no significant differences in reduction of hemoglobin level, blood coagulation level, and clinical outcomes. The transfusion rates were 4% in oral group and 5% IA group, respectively. Also, no significant differences were identified in thromboembolic complications.ConclusionOral TXA according to the described protocol demonstrated non-inferiority for primary TKA, with no safety concerns and a greatly reduced cost, compared with the IA TXA. This randomized controlled trial supports the oral administration of TXA in TKA.Trial registrationThe trial was registered in the Chinese Clinical Trial Registry (ChiCTR-INR-17010968) dated 23rd March 2017.

Highlights

  • Randomized controlled trials have confirmed oral tranexamic acid (TXA) can provide similar blood-sparing efficacy compared with intravenous (IV) TXA in total knee arthroplasty (TKA), some concerns do remain about thromboembolic events after such systemic administration

  • Oral administration of TXA had beneficial bloodand cost-saving effect, as confirmed in some randomized controlled trials (RCT), and reduced transfusions without increased risk of thromboembolic complications compared with placebo [14, 15]

  • Compared with oral or IV TXA, the IA TXA can provide a maximum concentration of TXA in surgical site and thereby a prolonged effect to reduce postoperative blood loss, but is associated with minimal levels of systemic absorption, which may increase safety

Read more

Summary

Introduction

Randomized controlled trials have confirmed oral tranexamic acid (TXA) can provide similar blood-sparing efficacy compared with intravenous (IV) TXA in total knee arthroplasty (TKA), some concerns do remain about thromboembolic events after such systemic administration. Many studies have confirmed that intra-articular (IA) application of TXA can show similar blood-saving efficacy with minimal levels of systemic absorption compared with IV TXA. It remains unclear whether the efficacy and safety of oral TXA administration is equal to or less than that of IA administration in TKA without the use of a tourniquet and drain. Numerous RCTs [16, 17] and meta-analyses [18] showed valid evidence favoring the effectiveness of various dosages and routes of IA TXA in reducing blood loss and allogeneic transfusion requirements in TKA

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.