Abstract

The hydrodynamic characteristics of a pulsed sieve plate extraction column (PSPEC) was studied experimentally using two different liquid phase systems, namely water/kerosene and 30%TBP (tributyl phosphate) in NPH (normal paraffin hydrocarbon)/0.3M HNO3. The aqueous phase as the dispersed phase and the organic phase as the continuous phase (phase reversal) and vice versa (normal phase operation) studies in a pulsed sieve plate extraction column 0.076m in diameter and 1m height are presented in this paper. The hydrodynamic properties like drop size and holdup are characterized as a function of various operating parameters namely pulse velocity, dispersed phase and continuous phase velocity and duty cycle of pulsing. Flooding in the column was also investigated for the changes involving flow ratio of continuous phase to that of the dispersed phase for both insufficient and excessive pulsing. It has been observed that phase reversal mode of operation is not efficient as compared to normal phase operation for the PSPEC.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.