Abstract

Purpose: The purpose of this study was to compare the changes in lower extremity muscle morphology and electromyography (EMG) signals during treadmill running (TR) and plastic track running (PR). Methods: A total of 10 healthy male runners aged 22.5±1.3 years, height: 175.5±4.5 cm; weight: 71.9±2.7 kg; BMI: 22.1±1.1 volunteered to participate in this study. Muscle morphology data were collected by a portable ultrasound scanner before and after running. Median frequency (MF), mean power frequency (MPF) and root mean square (RMS) were monitored during TR and PR. Results: The results indicated that muscle thickness and pennation angle have increased after running. The muscle thickness after PR showed significantly higher than TR in tested muscle except tibialis anterior (TA) and medial gastrocnemius (MG). In contrast, only the pennation angle of TA and lateral gastrocnemius (LG) after PR was significantly different from that after TR (P <0.001, P = 0.002). The most significant difference in the change rate of muscle thickness was found at TA. In addition, TA and MG showed significantly higher change rate of the pennation angle after TR than that after PR. Both of MF and MPF showed a downward trend after TR and PR. It could discover that the MF and MPF of LG during TR showed a significantly lower than that during PR both in two phases (P =0.001, P <0.001). However, in the last 5 minutes, MF and MPF of MQ during PR were smaller than that during PR (P = 0.001, P = 0.015). Furthermore, MF of RF during TR showed significantly different from that during PR (P = 0.017). From the point of RMS, in the first five minutes, the RMS of medical quadriceps (MQ), lateral quadriceps (LQ), hamstring muscles (HM) and MG during TR was significantly higher than that of PR (P <0.05). In addition, the RMS of all tested muscles after TR was significantly higher than after PR during the last 5 minutes (P <0.05). Conclusions: The current study indicated that TR and PR would cause different effects to lower extremity muscle morphology. In addition, the EMG signals based on running surfaces are also unconformity. Compared with the plastic track, the treadmill will bring more stimulation to the lower extremity muscles. The preliminary findings provide further insights into the rationality of runners’ choice of the running surface.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call