Abstract

To assess the accuracy of five creatinine clearance equations in predicting measured creatinine clearance in hospitalized patients with human immunodeficiency viral (HIV) infection. Prospective evaluation over a 6-month period. Erie County Medical Center, a 550-bed teaching institution. Forty-seven HIV-positive patients (39 men, 8 women) who were admitted for a variety of HIV-related illnesses and judged clinically to have stable renal function. Of the 47 original patients, 44 were evaluable based on exclusion criteria. Serum creatinine and 24-hour measured creatinine clearance were performed in each patient. The estimated creatinine clearance from each of the equations (Cockcroft-Gault, two Jeliffe equations, Mawer et al, and Hull et al) was compared with the measured creatinine clearance. Statistical analysis of these comparisons was performed and all of the equations were found to overestimate the measured creatinine clearance (mean error 34-45%). Many HIV-infected patients have a decreased creatinine clearance despite a serum creatinine concentration within the normal range. Each of the equations overestimated the measured creatinine clearance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.