Abstract

ObjectivesStandardized bite training is required to prevent oral hypofunction in elderly individuals. We aimed to compare masticatory muscle activity between 24 young adults and 16 pre-elderly individuals during a biting task using a novel standardized bite device (BD). MethodsThe BD was made of silicone rubber and included a high-force or low-force plate spring or no plate spring (dummy). The compressive stiffness of the material in each BD was measured using a texture analyzer. All participants performed a biting task 50-times at a rate of 1/s each using the three types of BDs on the right first molar. Electromyographic (EMG) activity was recorded bilaterally from the masseter and temporalis muscles. The variability of each biting training session was calculated as the coefficient of variance (CV) from the EMG activity during each biting task for each muscle. Masticatory muscle fatigue was assessed using a numerical rating scale (NRS). ResultsCompressive stiffness was significantly different between each BD (P < 0.001). The CV and NRS scores were not significantly different between the groups. The EMG activities during each bite task in all muscles were not significantly different for any measurement item between the age groups. The EMG activities of high- and low-force BDs in the right temporalis (ipsilateral) muscle were significantly higher than those of the dummy BD (P < 0.001). ConclusionsCompressive stiffness of the BD affected EMG activity only in the ipsilateral temporalis muscle, but not in the masseter or contralateral temporalis muscles, without any age effect.