Abstract

Thirty-nine patients admitted with proven subarachnoid haemorrhage were imaged both with 3-D time of flight (TOF) magnetic resonance angiography (MRA) and conventional angiography. As the definitive examination, catheter angiography demonstrated 37 aneurysms; ten patients had no aneurysm, the remaining 29 patients had 37 aneurysms. We found the sensitivity of 3-D TOF MRA for the detection of aneurysms to be 81% and specificity to be 100% when the reporting radiologist inspects not only the MIP reconstructions but also the MRA source data and the axial spin-echo images. The investigation is less accurate if all the available imaging data is not considered.