Abstract

DisclaimerIn an effort to expedite the publication of articles related to the COVID-19 pandemic, AJHP is posting these manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time.PurposeA study was conducted to compare an intravenous (IV) gravimetric technology–assisted workflow (TAWF) platform to an IV robotic system. In the study we reviewed both IV technology platforms using the same gravimetric quality assurance system, which allowed for direct comparison.MethodsAll oncology preparations compounded from January 2016 through December 2018 using either system were included in our retrospective analysis. Final preparation accuracy, IV system precision, and workflow throughput (analyzed using lean process methodologies) were evaluated.ResultsData analysis indicated that use of the IV gravimetric TAWF system was associated with a significantly lower percentage of accuracy errors compared to the IV robotics system (1.58% vs 2.47%, P < 0.001), with no significant difference in absolute precision (1.12 vs 1.12 P = 0.952). Lean analysis demonstrated that overall completion time (17:49 minutes vs 24:45 minutes) and compound preparation time (2:39 minutes vs 6:07 minutes) were less with the IV gravimetric TAWF vs the IV robotics system.Conclusion Implementation of either an IV gravimetric TAWF system or IV robotics system will result in similar compounding accuracy and precision. Preparation time was less with use of the IV gravimetric TAWF vs the IV robotic system, but the IV robotic system required less human intervention. Both systems ensure medication safety for patients, although the IV robotic system has increased safeguards in place. Therefore, the primary driver for implementing these systems is alternative factors such as cost of systems implementation and maintenance, employee safety, and drug waste.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.