Abstract

Objective The study aimed to compare the incidence of intraoperative endplate injury in patients who underwent Transforaminal interbody fusion (TLIF) and mini-open lumbar interbody fusion (LLIF) surgery. The independent risk factors related to endplate injury in LLIF procedure were analyzed. Methods A total of 199 patients who underwent LLIF (n = 106) or TLIF (n = 93) surgery from June 2019 to September 2021 were reviewed. The endplate injury was assessed by postoperative sagittal CT scan. A binary logistic analysis model were used to identify independent risk factors related to LLIF endplate injury based on univariate analysis. Results There was an obvious difference in the occurrence of intraoperative endplate injury between LLIF (42/106, 39.6%) and TLIF group (26/93, 28%), although it did not reach the significant level. L1 CT value (OR = 0.985, 95% CI = 0.972–0.998), cage position (OR = 3.881, 95% CI = 1.398–10.771) and height variance (OR = 1.263, 95% CI = 1.013–1.575) were independent risk factors for endplate injury in LLIF procedure. According to the cage settlement patterns, there 5 types of A to E. The severity of the facet joint degeneration was positively related to the occurrence of endplate injury. Conclusions The incidence of intraoperative endplate injury is higher in LLIF than in TLIF procedures. Low bone quantity, cage posterior position and larger height variance are risk factors to induce endplate injury in LLIF surgery. The facet joint degeneration may be related to severe endplate injuries and even fractures.