Abstract

Three different methods of obtaining the infrared spectrum of carbon-epoxy prepreg for quality control purposes are critically evaluated with respect to their suitability for quantitative analysis. They are: transmission using a cast film of resin, attenuated total reflection (ATR) using prepreg, and diffuse reflection (DR) using prepreg. The cast film method is subject to significant error resulting from nonuniform film thickness; careful sample preparation is necessary in order to obtain acceptable results. The ATR method is faster and easier to use than the transmission method and gives more reproducible results; the use of a 45° germanium prism is recommended. The DR method is not suitable for quantitative work because of complications arising from front-surface reflection effects; it can be very useful, however, as a qualitative method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.