Abstract

INTRODUCTION:While endovascular coiling has been shown to be a safe treatment option for intracranial aneurysms, there remains concern regarding increased recurrence and retreatment rates. Preliminary studies evaluating hydrogel coated coils have demonstrated decreased recurrence rates compared to bare metal coils.METHODS:A retrospective chart review was done on all patients with anterior communicating artery aneurysms (ACoAAs) treated with endovascular coiling between 2014 and 2018. Treatment groups were divided into hydrogel coated coils or bare metal coils. Patients were categorized into the hydrogel group when ≥ 70% of the coil length was hydrogel coated.RESULTS:Eighty-four ACoAAs were treated with coil embolization between 2014 and 2018. Postoperative imaging was available for 68 patients. Twenty-six patients were categorized into the hydrogel treatment group. Aneurysm recurrence was seen in 7.7% (2/26) of patients treated with hydrogel coated coils compared to 33.3% (14/42) of those treated with bare metal coils (P = 0.03). Subanalysis of patients with ruptured aneurysms revealed decreased recurrence rates in patients treated with hydrogel coated coils at 5.9% (1/17) compared to patients treated with bare metal coils at 39.4% (13/33) (P = 0.01).CONCLUSIONS:Hydrogel-coated coils may reduce recurrence rates in the treatment of both ruptured and unruptured ACoAAs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.