This paper presents an analysis of three different electrical machine topologies for a turbo circulator application. The electrical machines are designed to operate with 6 kW output power at 120 000 r/min. This paper demonstrates the design aspects of one solid rotor squirrel cage induction motor and two permanent magnet synchronous machines. The machines are compared using electromagnetic, thermal, and mechanical analyses. The benefits and disadvantages of each topology under study are discussed. For other high-speed applications presented, a comparative approach helps in selecting the suitable electrical machine topology by analyzing the performance criteria discussed. The prototype construction of one of the topologies is analyzed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.