Abstract

IntroductionMechanical cardiopulmonary resuscitation (CPR) devices are widely used to rescue patients from cardiac arrest. This study aimed to compare hemodynamic effects and resuscitation outcomes between a motor-driven, automatic simultaneous sterno-thoracic cardiopulmonary resuscitation device and the Lund University cardiac arrest system (LUCAS).Material and methodsAfter 2 minutes of electrically induced ventricular fibrillation (VF), Yorkshire pigs (weight 35–60 kg) received CPR with an automatic simultaneous sterno-thoracic CPR device (X-CPR group, n = 13) or the Lund University cardiac arrest system (LUCAS group, n = 12). Basic life support for 6 minutes and advanced cardiovascular life support for 12 minutes, including defibrillation and epinephrine administration, were provided. Hemodynamic parameters and resuscitation outcomes, including return of spontaneous circulation (ROSC), 24-hour survival, and cerebral performance category (CPC) at 24 hours, were evaluated.ResultsHemodynamic parameters, including aortic pressures, coronary perfusion pressure, carotid blood flow, and end-tidal carbon dioxide pressure were not significantly different between the two groups. Resuscitation outcomes were also not significantly different between the groups (X-CPR vs. LUCAS; rate of ROSC: 31% vs 25%, p = 1.000; 24-hour survival rate: 31% vs 17%, p = 0.645; neurological outcome with CPC ≤2: 31% vs 17%, p = 0.645). Also no significant difference in incidence complications associated with resuscitation was found between the groups.ConclusionsCPR with a motor-driven X-CPR and CPR with the LUCAS produced similar hemodynamic effects and resuscitation outcomes in a swine model of cardiac arrest.

Highlights

  • Mechanical cardiopulmonary resuscitation (CPR) devices are widely used to rescue patients from cardiac arrest

  • Resuscitation outcomes were not significantly different between the groups (X-CPR vs. Lund University cardiac arrest system (LUCAS); rate of return of spontaneous circulation (ROSC): 31% vs 25%, p = 1.000; 24-hour survival rate: 31% vs 17%, p = 0.645; neurological outcome with cerebral performance category (CPC) 2: 31% vs 17%, p = 0.645)

  • The quality of cardiopulmonary resuscitation (CPR) is well known to be a major determinant of survival and favorable neurological outcome in patients with cardiac arrest [2,3,4]

Read more

Summary

Objectives

This study aimed to compare hemodynamic effects and resuscitation outcomes between a motor-driven, automatic simultaneous sterno-thoracic cardiopulmonary resuscitation device and the Lund University cardiac arrest system (LUCAS)

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.