Abstract

Statement of problemAlthough the conventional chemicomechanical cord technique is widely used, packing the cord into the sulcus may cause pain and bleeding. Cordless displacement techniques have been introduced, but a comparison of these systems is lacking. PurposeThe purpose of this clinical study was to evaluate the efficiency and gingival response of 4 cordless gingival displacement systems. Material and methodsOne hundred twenty teeth in 30 participants were allocated to 4 groups according to the material used: Tr (Traxodent; Premier Dental Products Co), Es (Expasyl; Acteon UK), Ez (Expazen; Acteon UK), and Mr (3M Retraction; 3M ESPE). Baseline measurements of periodontal indices and a digital scan were acquired. The cordless displacement pastes were applied according to the manufacturer’s instructions. After removal, a second scan was acquired. Participants were recalled on the 2nd and 14th day to measure periodontal indices and for scans. Screenshots were superimposed to measure changes in the gingiva. Statistical differences among the different materials in achieving lingual and buccal vertical gingival displacement were tested using the related-samples Friedman 2-way ANOVA test by ranks at 3 time points such as immediate, at 2 days, and at 14 days (α=.05). ResultsImmediate gingival displacement varied with the system used. For horizontal displacement, median values ranged between 150 μm (Tr) and 725 μm (Ez) for buccal displacement and between 93 μm (Tr) and 550 μm (Ez) for lingual displacement. Minimum and maximum displacements also varied and followed a similar trend, with Traxodent providing the lowest displacement. The plaque index and attachment level did not statistically differ before and after the treatment. The periodontal parameters were not statistically significant among the groups at all time intervals, except for the gingival index that increased for all the groups after 2 days. ConclusionsSignificant differences were found among the 4 tested systems in both vertical and horizontal gingival displacement. Expasyl, Expazen, and 3M Retraction exceeded the 200-μm requirements for horizontal displacement. Traxodent provided the least displacement in both vertical and horizontal dimensions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.