Abstract

Numerous methods for quantitative fluorescence calibration (QFC) have been developed to quantify receptor expression on lymphocytes as potential disease biomarkers. CD20 expression in B-cell chronic lymphocytic leukemia (B-CLL) is one of the best examples of such a biomarker, but results from the use of different QFC methods vary considerably. We measured CD20 expression on normal and B-CLL B-cells, using FITC and PE conjugates from the same monoclonal antibody (Mab). As a biological control and calibrator, we also measured CD4 expression on T-cells with FITC and PE Mab. Calibration curves were constructed using the CLSI (formerly NCCLS) consensus guidelines for QFC. Calibration with QuantiBRITE PE-labeled microspheres and the use of unimolar PE conjugates provided direct measurement of antibody bound per cell (ABC) for CD4 and CD20. Calibration for FITC conjugates was based on molecules of equivalent soluble fluorochrome (MESF), as determined by NIST RM 8640 microsphere standards. These MESF values were then converted to ABC, using the CD4 T-cell as a biologic calibrator, to normalize FITC and PE results for CD20 expression. On normal B cells, the mean ABC value for unimolar CD20-PE conjugate was 143,500 (CV +/- 19.1%). The mean ABC value for B-CLL B-cells stained with the same conjugate was 21,700 (CV +/- 42.0%). Using the CD4 T-cell as a biologic calibrator for FITC conjugate, the mean ABC value for CD20-FITC on normal B-cells was 199,300. CD20-FITC staining on B-CLL cells was generally too weak for accurate quantification. On normal T-cells, the mean ABC value for CD4 unimolar PE conjugate was (36,800 +/- 10.4)%, and it did not differ significantly in CLL samples. The expression of CD20 on normal and B-CLL lymphocytes can be quantified in ABC units using unimolar CD20-PE conjugates. In addition, CD4 expression on T-cells can be used as a biological calibrator to quantify CD20-FITC ABC, with reasonable agreement between the two conjugates with different fluorochromes. Issues regarding the accuracy of MESF microsphere calibrators and effective F/P ratios for FITC conjugates will require additional laboratory studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.