Abstract
Performing liquefied natural gas (LNG) bunkering involves the risk of accidental leakage. When released from containment, LNG rapidly vaporizes into flammable natural gas and could lead to flash fire and explosion. Hence, LNG bunkering needs to take place in an area without an ignition source called a safety zone. This study compares the safety zone estimated by the Bunkering Area Safety Information for LNG (BASiL) model with that of the computational fluid dynamic (CFD) software FLACS, for Ro-Pax ferry bunkering. Horizontal leaks covering different wind speeds in eight wind directions were compared between the two models. Additionally, a grid refinement study was performed systematically to quantify the discretization error uncertainty in the CFD. Of 24 leak cases, FLACS and the BASiL model results agreed on 18 cases. In three cases validation was inconclusive due to the CFD error uncertainty. The BASiL model underestimated the safety zone distance in three cases compared with FLACS. Future work would be to perform a higher grid refinement study to confirm inconclusive comparison and examine ways to reduce gas dispersion spread for the worst result.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.