Abstract

To compare findings on hard copies of cranial ultrasound (US) and magnetic resonance imaging (MRI) obtained between birth and term in a group of preterm infants. Infants born at or below a gestational age of 30 weeks who underwent cranial US scan and MRI on the same day were eligible for this study. Infants underwent, whenever possible, 3 scans between birth and term. We calculated the predictive probability (PP) of US findings as a predictor of findings on MRI. Sixty-two paired MRI and US studies were performed between birth and term in 32 infants born at a median gestational age of 27 (range: 23-30) weeks and a median birth weight of 918 (530-1710) grams. US predicted some MRI findings accurately: germinal layer hemorrhage (GLH) on US had a PP of 0.8 with a 95% confidence interval of (0.70-0.90) for the presence of GLH on MRI, intraventricular hemorrhage (IVH) on US had a PP of 0.85 (0.76-0.94) for the presence of IVH on MRI, and severe white matter (WM) echogenicity on US had a PP of 0.96 (0.92-1.0) for the presence of WM hemorrhagic parenchymal infarction on MRI. Other MRI changes were less well-predicted: mild or no WM echogenicity on US had a PP of 0.54 (0.41-0.66) for the presence of normal WM signal intensity on MRI, and moderate or severe WM echogenicity on US had a PP of 0.54 (0.42-0.66) for the presence of small petechial WM hemorrhage and/or diffuse excessive high-signal intensity (DEHSI) in the WM on T2-weighted images on MRI. However, mild/moderate or severe WM echogenicity on US scans performed at >/=7 days after birth had a PP of 0.72 (0.58-0.87) for the presence of WM hemorrhage and/or DEHSI on MRI. There were no cases of cystic periventricular leukomalacia. US accurately predicted the presence of GLH, IVH, and hemorrhagic parenchymal infarction on MRI. However, its ability to predict the presence of DEHSI and small petechial hemorrhages in the WM on T2 weighted images is not as good, but improves on scans performed at >/=7 days after birth. In addition, normal WM echogenicity on US is not a good predictor of normal WM signal intensity on MRI.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.