Abstract

We aimed to compare apical canal transportation of extracted teeth and two types of simulated resin blocks. Mesiobuccal root of extracted maxillary molars, high hardness simulated resin blocks (Knoop hardness=40) and low hardness simulated resin blocks (Knoop hardness=22) were prepared with K-files using step-back technique (n=15 canals in each group). Double exposure radiographic technique was used for extracted teeth. Simulated resin blocks were stabilized and scanned before and after preparation. Pre and post-preparation pictures were superimposed and apical transportation was measured. The data were analyzed statistically using ANOVA and Tukey HSD tests. There was no significant difference in apical canal transportation between extracted teeth and high hardness resin blocks (P>0.05). Low hardness resin blocks showed more apical transportation than the other groups (P<0.05). Under the conditions of this study, apical canal transportation for extracted teeth and high hardness simulated resin blocks were similar.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.