Abstract

The three-microphone and four-microphone methods have been shown useful for measuring the characteristic impedance and propagating wavenumber of porous materials. In this paper the effects of uncertainties in the apparatus and pressure transfer function measurements are analyzed using Monte Carlo methods. It is shown that for materials with low flow resistivities the four-microphone method is appreciably more accurate than the three-microphone method at low frequencies. The dominant contributors to the overall error are uncertainty in the magnitude and phase of the transfer function measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.