Rational use of energy and power is a key to the economic development of human society and to achieve sustainable environment. Power and energy have been the major contributors to the global warming and researchers around the world have put a lot of effort to find new ways to save and control energy through energy efficient measures. Earth pipe cooling technology is considered as one of the viable options to save energy for a hot and humid subtropical climate. This paper presents the comparison of earth pipe cooling performance between two different piping systems for a hot and humid subtropical climatic zone in Queensland, Australia. Two different piping systems of vertical and horizontal were laid in the ground in order to compare the cooling performance. A thermal model is developed for the earth pipe cooling system using ANSYS Fluent. Data were collected from two modelled rooms connected with the two different piping layouts and systems. Impact of air temperature and velocity on room cooling performance is also assessed. A temperature reduction is observed for both the piping systems. The results indicate that the vertical piping system shows better performance in comparison with the horizontal piping system.

Highlights

  • Sustainable development has become one of the significant considerations in the design and execution of development policies in the world

  • Experimental results were obtained for air velocity and air temperature at the pipe inlet and different points of the modelled rooms

  • Measured room temperature of both vertical earth pipe cooling (VEPC) and horizontal earth pipe cooling (HEPC) system was compared with the standard room temperature which are shown in Figure 3(a) and 3(b)

Read more

Summary

Introduction

Sustainable development has become one of the significant considerations in the design and execution of development policies in the world. Passive air cooling of earth pipe cooling (EPC) system is a viable option to reduce the energy consumption in the buildings for most of the warm climatic zones including subtropical climate. For measuring the performance of VEPC system, average air temperature and velocity were collected from both the rooms by turning off the HEPC system.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.