Abstract
BackgroundGraft choices other than left anterior descending artery (LAD)–internal thoracic artery (ITA) anastomosis in coronary artery bypass grafting (CABG) surgery are still controversial. Although 2-dimensional transthoracic echocardiography (2D TTE) is still the most commonly used method, more is needed to diagnose myocardial dysfunction. Ventricular strain values obtained by speckle tracking echocardiography (STE) or tissue Doppler imaging (TDI) methods can much better detect subclinical changes. This study aims to detect early postoperative myocardial function changes compared to single ITA/Bilateral Internal Thoracic Artery (BITA) use by measuring 3-dimensional ejection fraction (3D EF) and ventricular strain values and comparing them according to graft preference.MethodsThe study included 35 isolated CABG patients. All patients underwent on-pump CABG via sternotomy. The patients were divided into two groups using single ITA and BITA. Preoperative and postoperative 1st-week 3D EF and ventricular strain values of the patients were calculated using semi-automatic software. The recorded data were compared and evaluated between the two groups.ResultsOf The 35 patients participating in the study, 74.3% (n = 26) were male, 25.7% (n = 9) were female, and their average age was 62.7 ± 7.9 years. Preoperative 3D EF values of the patients were 54.4 ± 8.3% and postoperative 49.5 ± 8.2%. The mean preoperative Apical Long Axis Longitudinal Strain (APLAX LS) was calculated as − 16.2 ± 5.0%, 4 Chambers Longitudinal Strain (4CH LS)–16.8 ± 4.6%, 2 Chambers Longitudinal Strain (2CH LS) − 17.0 ± 4.9%, and Global Longitudinal Ventricular Strain (GLVS) − 16.7 ± 4.2%. Postoperative strain values were measured as − 15.1 ± 4.8%, − 14.7 ± 4.9%, − 14.6 ± 5.6% and − 14.8 ± 4.6%, respectively. When the groups were evaluated within themselves, the mean preoperative 3D EF of the patients in the single ITA group was 52.5 ± 8.8%, while the postoperative mean was 47.7 ± 6.0%. In the BITA group, preoperative 3D EF was 56.3 ± 7.5 and postoperative 51.4 ± 9.8. A decrease in strain values was detected in all groups except APLAX planes.ConclusionsIn our study, no statistically significant difference was observed in terms of myocardial function changes according to the use of ITA/BITA. However, the decline in postoperative strain values of patients in the BITA group was more remarkable, and it was thought that this may be due to prolonged aortic cross clamp (CC) and cardiopulmonary bypass (CPB) times.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.