Abstract

To compare the performances of different microwave measure methods in UC content determination, we have developed two measurement systems that can be operated in 12–15 GHz band, including one based on free space method, and the other based on waveguide method. The fly ash samples with UC content in 0–20% are measured. In addition, this paper specifically studies the test results in the 0–2% low UC content range using the waveguide method. The measurement range and measure accuracy are analyzed to evaluate these methods. For measurement range, free space method can realize wider measurement range of UC content compared with waveguide method. For accuracy, the error of UC content is used as an accuracy indicator to evaluate accuracies under different test modes. The calculated accuracy indicators can verify the following conclusions. The waveguide method is superior to the free space method and the accuracy of using the magnitude as the measurement parameter is lower than that of using the phase in both measurement systems.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.