Abstract

Statement of problemInformation about the accuracy of intraoral scanners for the edentulous maxilla is lacking. PurposeThe purpose of this in vitro study was to compare the accuracy of 3 different intraoral scanner techniques on a completely edentulous maxilla typodont. Material and methodsTwo completely edentulous maxillary typodonts with (wrinkled typodont) and without (smooth typodont) palatal rugae were used as reference and were scanned by using an industrial metrological machine to obtain 2 digital reference scans in standard tessellation language (STL) format (dWT and dST). Three different scanning techniques were investigated: in the buccopalatal technique, the buccal vestibule was scanned with a longitudinal movement ending on the palatal vault with a posteroanterior direction; the S-shaped technique was based on an alternate palatobuccal and buccopalatal scan along the ridge; in the palatobuccal technique, the palate was scanned with a circular movement and then with a longitudinal one along the buccal vestibule. Consecutively, 6 types of scans were obtained (n=10), namely wrinkled typodont/buccopalatal technique, wrinkled typodont/S-shaped technique, wrinkled typodont/palatobuccal technique (wrinkled typodont), smooth typodont/buccopalatal technique, smooth typodont/S-shaped technique, and smooth typodont/palatobuccal technique (smooth typodont). Scans in STL format were imported into a dedicated software program, and trueness and precision were evaluated in μm. In addition to descriptive statistics (95% confidence interval), a 2-factor ANOVA on the data ranks, the Kruskal-Wallis, and the Dunn tests were performed to analyze differences among groups (α=.05). ResultsMean values for trueness (95% confidence interval) were wrinkled typodont/buccopalatal technique=48.7 (37.8-59.5); wrinkled typodont/S-shaped technique=65.9 (54.9-77.4); wrinkled typodont/palatobuccal technique=109.7 (96.1-123.4); smooth typodont/buccopalatal technique=48.1 (42.4-53.7); smooth typodont/S-shaped technique=56.4 (43.9-68.9); smooth typodont/palatobuccal technique=61.1 (53.3-69), with statistically significant differences for wrinkled typodont/buccopalatal technique versus wrinkled typodont/palatobuccal technique (P<.001), buccopalatal technique versus palatobuccal technique (P<.001), and wrinkled typodont versus smooth typodont (P=.002). Mean values for precision (95% confidence interval) were wrinkled typodont/buccopalatal technique=46.7 (29.7-63.7); wrinkled typodont/S-shaped technique=53.6 (37.6-69.7); wrinkled typodont/palatobuccal technique=90 (59.1-120.9); smooth typodont/buccopalatal technique=46 (39.7-52.3); smooth typodont/S-shaped technique=76 (55.5-96.6); smooth typodont/palatobuccal technique=52.9 (41.9-63.8); with statistically significant differences for buccopalatal technique versus palatobuccal technique (P=.032) and wrinkled typodont/buccopalatal technique versus wrinkled typodont/palatobuccal technique (P=.012). ConclusionsSmooth typodont scans showed better trueness than wrinkled typodont scans. Buccopalatal technique showed better mean values for trueness and precision than palatobuccal technique only in the wrinkled typodont scenario, while the other scanning approaches did not show significant differences in either tested configuration.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.