Abstract

There is increasing evidence that left atrial (LA) size is an important predictor of adverse cardiovascular outcomes such as atrial fibrillation, stroke, and congestive heart failure. The aim of this study was to determine whether there is a difference in results of quantification of LA volume by the area-length and Simpson's methods using multislice computed tomography (MSCT). The study population consisted of 51 patients with sinus rhythm (sinus group) and 20 patients with atrial fibrillation (af group) clinically indicated for MSCT angiography for evaluation of coronary arteries. Maximum LA volume, obtained at end-systole from the phase immediately preceding mitral valve opening, was measured using the area-length and Simpson's methods. In the sinus group, the mean LA volumes, indexed to body surface area, were 48.4+/-17.9 ml/m(2) with the area-length method and 48.3+/-17.0 ml/m(2) with the Simpson's method. In the af group, the mean indexed LA volumes with the area-length method and the Simposon's method were 91.5+/-47.5 ml/m(2) and 90.3+/-45.9 ml/m(2), respectively. LA volumes calculated by the area-length method exhibited a strong linear relationship and agreement with those calculated using Simpson's method in both the groups (sinus group: r=0.99, P<0.0001, af group: r=0.99, P<0.0001). The area-length method is a simple and reproducible means of assessment of LA volume. Standardization of LA volume assessment using MSCT is important for serial follow-up and meaningful communication of results of testing among institutions and physicians.