Abstract

To compare measurements from human skulls and their images from cephalometric radiographs (CR) and computed tomography (CT) scanograms, in order to gauge the potential clinical use of the latter. Based on specific inclusion criteria, including stable centric occlusion, 13 adult skulls were selected from a larger collection. The mandible was taped to the maxilla after securing the occlusion of teeth and condylar seating in the glenoid fossa. Lateral and posteroanterior cephalographs and CT 'scout views' were taken of each skull by standardized methods. Landmarks were identified on skulls and images. Linear measurements were made on all three records; angular measurements only on CR and CT images. Intraclass correlation coefficients (r) were calculated to assess similarity among records. Paired t-tests were used to compare differences between mean measurements. No statistically significant differences were noted between mean angular values on CR and CT views (P > 0.05). The highest correlations were observed for several vertical midline distances between CT and direct skull measures: 0.82 < r < 0.995-greatest for nasion-menton. For sagittal distances, the highest correlation was between the direct measure of condylion-pogonion and its CR image (r= 0.73). Correlations between CR and skull transverse measures were higher (0.46 < r < 0.80) than the corresponding skull vs. CT measures (0.06 < r < 0.38). CT and CR images are 2D slices and projections, respectively, of 3D structures. Vertical CT and skull measures correspond because the CT projection reflects a 1:1 ratio in the midsagittal plane; CT projected lateral images are smaller than the skull measures. The CR image reflects a distortion (approximately 8%) that brings Co-Pg closer to its anatomic distance, inadvertently contributing to better clinical planning, particularly in orthognathic surgery. The pattern of distortion of PA images was in opposite directions for CR and CT views. Cephalograms and CT scanograms are close in depicting angular relations of structures, but they differ in the accuracy of imaging linear measurements, because the location and size of an object within the imaged 3D structure varies with both records. Logistic and economic considerations favor the use of cephalographs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.