Abstract
This paper presents an experimental comparison of tactile array versus force-torque sensing for localizing contact during manipulation. The manipulation tasks involved rotating objects and translating objects using a planar two fingered manipulator. A pin and a box were selected as limiting cases of point and line contact against a cylindrical robot finger tip. Practical implementations of the two sensor types are compared theoretically and experimentally, and three different localization algorithms for the tactile array sensor are considered. Force-torque contact sensing results suffered from difficulties in calibration, transient forces, and low grasp force. Tactile array sensing was immune to these problems and the effect of shear loading was only noticeable for a simple centroid algorithm. The results show that with care, both of these sensing schemes can determine the contact location within a millimeter during real manipulation tasks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.