Abstract

This study was mainly framed to study the difference in tumor volumes as seen on computed tomography (CT) and magnetic resonance (MR) and their significance in planning. Twenty-five patients with brain tumor of different diagnoses who underwent stereotactic radiotherapy were included in this study. CT and MR imaging was done for all the patients with 2.5 mm slice thickness. The CT tumor volume and MR tumor volume were measured and compared with each other. The center of mass (CM) of the tumor volume delineated on CT and MR were computed and the shift between the two CMs was determined. The mean and median volume of the tumor as measured from MR scans was 19.67 cc +/- 13.73 and 16.13 cc (range: 3.25 cc-50.37 cc). Similarly, the mean and median volume of the tumor as measured from CT scans was 15.05 cc +/- 10.13 and 11.63 cc (range: 3.0 cc-36.25 cc) respectively. The mean and median CM shift between CT and MR was 5.47 mm and 5.21 mm respectively. The study demonstrates that MR is an indispensable imaging modality in radiotherapy for planning brain tumors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.