Abstract

BackgroundTwo common techniques used in canteen hygiene supervision, are the coliform paper assay, which is the standard method, and the adenosine triphosphate (ATP) bioluminescence method. The coliform paper assay requires the incubation of the sample, which is time-consuming and does not provide a real-time assessment. Meanwhile, the ATP bioluminescence assay can provide real-time kitchenware cleanliness data. ObjectiveThis study aimed to compare these two methods for evaluating the sanitary condition of kitchenware and explore whether the ATP bioluminescence assay can be used as a standard method in sanitary inspection. MethodsIn this study, the cluster random sampling method was used to sample kitchenware from six canteens in the Hebei province, China. Samples were, assessed through the coliform paper test and ATP bioluminescence assay. ResultsKitchenware negative rates for the coliform paper method and the ATP test were 64.39% and 49.07%, respectively. The Escherichia coli positive detection rate grew steadily as the relative light units (RLU) value for the ATP technique increased. The kappa coefficient for the two methods was 0.549, indicating that the two methods yield relatively consistent results. ConclusionAlthough currently not considered a standard method, simply using ATP detection is advantageous for quick on-site detection in catering unit hygiene supervision.