Abstract

Functional mitral regurgitation is associated with both annular and ventricular distortion. Aggressive reduction annuloplasty for functional mitral regurgitation acts primarily at the annulus, with variable impact on the left ventricle. The Coapsys device externally reshapes the left ventricle to correct functional mitral regurgitation. Left ventricular reshaping was analyzed in a randomized study. The RESTOR-MV study randomizes patients with coronary artery disease and functional mitral regurgitation to either reduction annuloplasty and coronary artery bypass grafting (the RA group) or Coapsys annuloplasty and bypass grafting (the CO group). The Coapsys device consists of epicardial pads connected by a cord. It was placed without cardiopulmonary bypass under echocardiographic guidance and sized to reduce annular dimension and improve leaflet coaptation. Internal reduction annuloplasty was performed by device placement. Intraoperative transesophageal echocardiograms were analyzed in 7 patients having reduction annuloplasty and 7 having Coapsys annuloplasty. Baseline mitral regurgitation (0-4 scale) was similar for the RA (3.0 +/- 0.6) and the CO groups (3.0 +/- 0.6). Intraoperative mitral regurgitation was reduced from 2.86 +/- 0.7 to 0.5 +/- 0.7 (P < .01 pre vs post) for the RA group and from 2.64 +/- 0.9 to 05 +/- 0.7 (P < .01 pre vs post) for the CO group. Annular anteroposterior diameter was reduced with both techniques: RA, 3.45 +/- 0.39 to 2.34 +/- 0.37 cm (P < .01 pre vs post); CO, 3.40 +/- 0.27 to 2.85 +/- 0.34 cm (P < .05 pre vs post). Long-axis dimensions were unchanged with both techniques. Short-axis dimensions measured at three levels were significantly reduced only in the CO patients: basal diameter 4.77 +/- 0.58 to 3.58 +/- 0.38 cm (P < .01 pre vs post); mid diameter 4.88 +/- 0.55 to 3.57 +/- 0.43 cm (P < .01 pre vs post); and apical diameter 4.39 +/- 0.46 to 3.38 +/- 0.34 cm (P < .01 pre vs post). Coapsys and reduction annuloplasty techniques both acutely reduce functional mitral regurgitation and annular dimension. The Coapsys device provided significantly greater left ventricular reshaping than did reduction annuloplasty. Further evaluation will assess the long-term valvular function and ventricular geometric stability associated with both techniques.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.