Abstract

Determinations of Chlorophyll a (Chl a) in eutrophic coastal marine waters were compared using N, N-dimethylformamide (DMF) and 90% acetone techniques. Measured Chl a concentrations ranged from 0.89 to 10.65 μg l−1 for 90% acetone extracts and from 0.97 to 12.92 μg l−1 for DMF extracts, respectively, for 24 surface water samples from the Harima-nada, Seto Inland Sea, Japan. Chl a concentrations using DMF as a solvent were consistently higher than those found using 90% acetone (p < 0.001, n= 24). Chl a is thus likely to be underestimated (by 13%) when 90% acetone is used for eutrophic waters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.