Abstract

Biological monitoring for occupational lead exposure involves routine venous blood draws from exposed employees. This uncomfortable procedure normally yields more blood than what is needed for analysis. Capillary blood sampling is less invasive but introduces the possibility of surface contamination. The objective of this study was to compare venous and capillary (earlobe) blood lead samples obtained from occupationally exposed individuals. Phlebotomists trained specifically in the collection of blood samples for lead determination collected 2 venous blood samples and 2 capillary earlobe samples from each participating employee. Before the capillary draw, the employee's earlobe was cleansed with an alcohol wipe in an effort to remove potential lead contamination. A second alcohol wipe was then used to sanitize the lancing area and was retained for lead analysis. Both the venous and capillary samples were subsequently analyzed with the use of graphite furnace atomic absorption spectrometry (GFAAS). GFAAS of venous blood specimens was considered the reference method of sampling and analysis. We collected and analyzed 126 paired earlobe and venous samples. Earlobe sampling was preferred to venous sampling by 54% of the employees surveyed. The mean difference between the capillary and venous results was 38.8 ± 48.1 μg/dL. Lead concentrations in earlobe blood were more than twice those found in venous samples in more than half of the samples (64 of 126). Despite simple cleansing with an alcohol wipe and no visible skin contamination, 94% of the wipe samples from earlobes contained more than 1 μg of lead. Even low concentrations of contamination can significantly alter the concentration of lead in the blood; for example, sample contamination of 0.3 μg lead in a 200-μL blood sample would yield an increase of 150 μg/dL in the measured lead concentration. The findings of this study suggest that until satisfactory skin cleansing and decontamination techniques are identified and evaluated, earlobe sampling should be avoided in the surveillance of occupational blood lead levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.