Abstract

Eighty patients had cardiopulmonary bypass (CPB), half having short (109 +/- 11 minutes) perfusions and half having long (188 +/- 14 min) perfusions. Twenty patients in each group were perfused with bubble oxygenators (Bentley, Harvey, or Galen) and 20 with membrane oxygenators (Modulung or Teflo). Hemodilution to a hematocrit value of 22.5% +/- 1.4% and hypothermia to 28 degrees +/- 2 degrees C were used in all patients. Complete hemograms, sequential multiple analyzer 18 tests, coagulation profiles, blood gases and pH, three immunoglobulins, and two complement fraction proteins were sampled as follows: three times before perfusion, one to ten times during perfusion, 1 hour immediately after perfusion, and 4, 24, and 48 hours postoperatively. Data in concentration terms were compared statistically and reported as mean and standard error for each subset. Additionally, rates of gain or loss were calculated in terms of quantity per liter of blood pumped per minute. During perfusion for both duration sets, use of a membrane oxygenator resulted in greater pump flows (4.55 +/- 0.15 L/min versus 3.75 +/- 0.11 L/min), lower total peripheral resistances (1,125 +/- 63 dynes.sec.cm-5 versus 1,652 +/- 115 dynes.sec.cm-5), and greater urinary outputs (9.4 +/- 1.1 ml/min versus 2.2 +/- 0.6 ml/min) than in the bubble oxygenator subsets. Comparisons of measured and calculated data in the immediate postperfusion interval showed no differences between bubble and membrane oxygenator subsets for short perfusions. In long perfusions, the membrane subset had lower plasma hemoglobin and white cell concentrations and generation rates, smaller (3 to 8 1/2 times) losses of IgG, IgM, C3 and shed blood necessitating less transfusion, and greater C4 losses. The membrane oxygenator systems used were more complex and costly and offered no advantages for short perfusion in adults. In anticipated long perfusions or where bleeding may be a problem, a membrane oxygenator appears more efficacious than bubble systems. For perfusions of less than 2 hours, membrane oxygenators had no biochemical or hematologic advantage over the bubble devices used in this study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.