Abstract

The paper summarizes the attenuation coefficient of the neutron fluence with E > 0.5 MeV through a reactor pressure vessel for vodo-vodyanoi energetichesky reactor (VVER) reactor types measured and/or calculated for mock-up experiments, as well as for operated nuclear power plant (NPP) units. The attenuation coefficient is possible to evaluate directly only by using the retro-dosimetry, based on a combination of the measured activities from the weld sample and concurrent ex-vessel measurement. The available neutron fluence attenuation coefficients (E > 0.5 MeV), calculated and measured at a mock-up experiment simulating the VVER-440-unit conditions, vary from 3.5 to 6.15. A similar situation is used for the calculations and mock-up experiment measurements for the VVER-1000 RPV, where the attenuation coefficient of the neutron fluence varies from 5.99 to 8.85. Because of the difference in calculations for the real units and the mock-up experiments, the necessity to design and perform calculation benchmarks both for VVER-440 and VVER-1000 would be meaningful if the calculation model is designed adequately to a given unit.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.